ADIS16250/ADIS16255
Rev. B | Page 3 of 20
SPECIFICATIONS
T
A
= −40°C to +85°C, V
CC
= 5.0 V, angular rate = 0°/sec, ±1 g, ±320°/sec range setting, unless otherwise noted.
Table 1.
Parameter Conditions Min Typ Max Unit
SENSITIVITY
1
Clockwise rotation is positive output
25°C, dynamic range = ±320°/sec
2
0.07326 °/sec/LSB
25°C, dynamic range = ±160°/sec 0.03663 °/sec/LSB
25°C, dynamic range = ±80°/sec 0.01832 °/sec/LSB
Initial Tolerance 25°C, dynamic range = ±320°/sec ±0.2 ±1 %
Temperature Coefficient ADIS16250 (see Figure 8) 225 ppm/°C
ADIS16255 (see Figure 11) 25 ppm/°C
Nonlinearity Best fit straight line 0.1 % of FS
BIAS
In Run Bias Stability 25°C, 1σ 0.016 °/sec
Turn-On-to-Turn-On Bias Stability 25°C, 1σ 0.05 °/sec
Angular Random Walk 25°C, 1σ 3.6 °/√hour
Temperature Coefficient ADIS16250 (see Figure 7) 0.03 °/sec/°C
ADIS16255 (see Figure 10) 0.005 °/sec/°C
Linear Acceleration Effect Any axis 0.2 °/sec/g
Voltage Sensitivity V
CC
= 4.75 V to 5.25 V 1.0 °/sec/V
NOISE PERFORMANCE
Output Noise At 25°C, ±320°/sec range, no filtering 0.48 °/sec rms
At 25°C, ±160°/sec range, 4-tap filter setting 0.28 °/sec rms
At 25°C, ±80°/sec range, 16-tap filter setting 0.14 °/sec rms
Rate Noise Density
At 25°C, f = 25 Hz, ±320°/sec range,
no filtering
0.056 °/sec/√Hz rms
FREQUENCY RESPONSE
3 dB Bandwidth
See the
Analog Bandwidth section for
adjustment
50 Hz
Sensor Resonant Frequency 14 kHz
SELF-TEST STATE
Change for Positive Stimulus 320°/sec dynamic range setting 439 721 1092 LSB
Change for Negative Stimulus 320°/sec dynamic range setting −439 −721 −1092 LSB
Internal Self-Test Cycle Time 20 ms
TEMPERATURE SENSOR
Output at 25°C 0 LSB
Scale Factor 6.88 LSB/°C
ADC INPUT
Resolution 12 Bits
Integral Nonlinearity ±2 LSB
Differential Nonlinearity ±1 LSB
Offset Error ±4 LSB
Gain Error ±2 LSB
Input Range 0 2.5 V
Input Capacitance During acquisition 20 pF
ON-CHIP VOLTAGE REFERENCE 2.5 V
Accuracy At 25°C −10 +10 mV
Temperature Coefficient ±40 ppm/°C
Output Impedance 70
Page view 2
1 2 3 4 5 6 7 8 ... 19 20

Comments to this Manuals

No comments

Second Wind Luftfilter Benutzerhandbücher

Beginnend mit N

Klicken Sie auf den Alphabet unten, um zur vollständigen Liste der Modelle zu gelangen, die mit diesem Buchstaben beginnen

Modelle Dokumententyp
Noble 6018
Installationshandbuch   Second Wind Noble 6018 Unit installation, 10 Seiten