MAX8759
Low-Cost, SMBus, CCFL Backlight Controller
22 ______________________________________________________________________________________
Table 3. Commands Description
DATA-REGISTER BIT ASSIGNMENT
SMBus
COMMAND
POR
STATE
(MSB)
BIT 4
BIT 3 BIT 2 BIT 1
BIT 0
(LSB)
0xFF
BR7 BRT6 BRT5 BR4 BRT3 BRT2 BRT1 BRT0
Read and
Write
0x01
0x00 Reserved Reserved ALSDEL1 ALSDEL0 ALS_CTL PWM_MD PWM_SEL
N/A Reserved Reserved Reserved Reserved LAMP_STAT OV_CURR Reserved
0x00 MFG4 MFG3
MFG1
0x00
ALS4
ALS3 ALS2 ALS1 ALS0
Read and
Write
0x05
0x00 ALSLL7 ALSLL6 ALSLL5 ALSLL4
ALSLL2 ALSLL1
0xFF ALSHL7 ALSHL6 ALSHL5 ALSHL4 ALSHL3 ALSHL2 ALSHL1
SMBCLK
A = START CONDITION.
B = MSB OF ADDRESS CLOCKED INTO SLAVE.
C = LSB OF ADDRESS CLOCKED INTO SLAVE.
D = R/W BIT CLOCKED INTO SLAVE.
AB CD
E
FG H
I
J
SMBDATA
t
SU:STA
t
HD:STA
t
LOW
t
HIGH
t
SU:DAT
t
HD:DAT
t
SU:DAT
t
SU:STO
t
BUF
K
E = SLAVE PULLS SMBDATA LINE LOW.
F = ACKNOWLEDGE BIT CLOCKED INTO MASTER.
G = MSB OF DATA CLOCKED INTO MASTER.
H = LSB OF DATA CLOCKED INTO MASTER.
I = ACKNOWLEDGE CLOCK PULSE.
J = STOP CONDITION.
K = NEW START CONDITION.
Figure 10. SMBus Read Timing
Comments to this Manuals