General Description
The MAX6657/MAX6658/MAX6659 are precise, two-
channel digital temperature sensors. Each accurately
measures the temperature of its own die and one
remote PN junction, and reports the temperature in digi-
tal form on a 2-wire serial interface. The remote junction
can be a diode-connected transistor like the low-cost
NPN type 2N3904 or 2N3906 PNP type. The remote
junction can also be a common-collector PNP, such as
a substrate PNP of a microprocessor.
The 2-wire serial interface accepts standard System
Management Bus (SMBus™) commands such as Write
Byte, Read Byte, Send Byte, and Receive Byte to read
the temperature data and program the alarm thresholds
and conversion rate. The MAX6657/MAX6658/
MAX6659 can function autonomously with a program-
mable conversion rate, which allows the control of sup-
ply current and temperature update rate to match
system needs. For conversion rates of 4Hz or less, the
temperature is represented in extended mode as 10
bits + sign with a resolution of 0.125°C. When the con-
version rate is faster than 4Hz, output data is 7 bits +
sign with a resolution of 1°C. The MAX6657/
MAX6658/MAX6659 also include an SMBus timeout
feature to enhance system reliability.
Remote accuracy is ±1°C between +60°C and +100°C
with no calibration needed. The MAX6657 measures
temperatures from 0°C to +125°C and the MAX6658/
MAX6659 from -55°C to +125°C. The MAX6659 has the
added benefit of being able to select one of three
addresses through an address pin, and a second over-
temperature alarm pin for greater system reliability.
Applications
Desktop Computers Workstations
Notebook Computers
Servers
Features
Dual Channel: Measures Remote and Local
Temperature
11-Bit, 0.125°C Resolution
High Accuracy ±1°C (max) from +60°C to +100°C
(Remote)
No Calibration Required
Programmable Under/Overtemperature Alarms
Programmable Conversion Rate
(0.0625Hz to 16Hz)
SMBus/I
2
C™-Compatible Interface
Two Alarm Outputs: ALERT and OVERT1
(MAX6657 and MAX6658)
Three Alarm Outputs: ALERT, OVERT1,
and OVERT2 (MAX6659)
MAX6657/MAX6658/MAX6659
±1°C, SMBus-Compatible Remote/Local Temperature
Sensors with Overtemperature Alarms
________________________________________________________________ Maxim Integrated Products 1
19-2034; Rev 1; 10/01
Ordering Information
PART
TEMP.
RANGE
PIN-
PACKAGE
MEASURED
TEMP. RANGE
MAX6 657MSA -55°C to +125°C 8 SO 0°C to +125°C
MAX6 658MSA -55°C to +125°C 8 SO -55°C to +125°C
MAX6 659MEE -55°C to +125°C 16 QSOP -55°C to +125°C
SMBus is a trademark of Intel Corp.
I
2
C is a trademark of Philips Corp.
16
15
14
13
12
11
10
9
1
2
3
4
5
6
7
8
V
CC
N.C.
STBY
SMBCLK
N.C.
SMBDATA
N.C.
OVERT2
ALERT
TOP VIEW
MAX6659
QSOP
N.C.
DXP
OVERT1
DXN
ADD
GND
GND
ALERT
GNDOVERT1
1
2
8
7
SMBCLK
SMBDATADXP
DXN
V
CC
SO
3
4
6
5
MAX6657
MAX6658
Pin Configurations
For pricing, delivery, and ordering information, please contact Maxim/Dallas Direct! at
1-888-629-4642, or visit Maxim’s website at www.maxim-ic.com.
Typical Operating Circuit appears at the end of the
data sheet.
Page view 0
1 2 3 4 5 6 ... 16 17

Summary of Contents

Page 1 - MAX6657/MAX6658/MAX6659

General DescriptionThe MAX6657/MAX6658/MAX6659 are precise, two-channel digital temperature sensors. Each accuratelymeasures the temperature of its ow

Page 2

MAX6657/MAX6658/MAX66591) Put the MAX6657/MAX6658/MAX6659 into standbymode by setting bit 6 of the Configuration register to1. Initiate a one-shot con

Page 3

Alarm Threshold RegistersFour registers store ALERT threshold values—one high-temperature (THIGH) and one low-temperature (TLOW)register each for the

Page 4

MAX6657/MAX6658/MAX6659For example, OVERT1 has a threshold set to +50°Cand is connected to a fan. OVERT2 has a threshold of+75°C and is connected to a

Page 5

MAX6657/MAX6658/MAX6659______________________________________________________________________________________ 13Status Byte FunctionsThe status byte (

Page 6

MAX6657/MAX6658/MAX6659control can be used to reduce the supply current inportable-equipment applications. The conversion ratebyte’s POR state is 08h

Page 7

MAX6657/MAX6658/MAX6659______________________________________________________________________________________ 15Chip InformationTRANSISTOR COUNT: 16,9

Page 8

MAX6657/MAX6658/MAX665916 ______________________________________________________________________________________SOICN.EPSPackage Information±1°C, SMBu

Page 9

MAX6657/MAX6658/MAX6659Maxim cannot assume responsibility for use of any circuitry other than circuitry entirely embodied in a Maxim product. No circu

Page 10

MAX6657/MAX6658/MAX66592 _______________________________________________________________________________________ABSOLUTE MAXIMUM RATINGSStresses beyon

Page 11

MAX6657/MAX6658/MAX6659_______________________________________________________________________________________ 3Note 1: TA= +25°C to +85°C.Note 2: If

Page 12

MAX6657/MAX6658/MAX66594 _______________________________________________________________________________________Typical Operating Characteristics(VCC=

Page 13

MAX6657/MAX6658/MAX6659_______________________________________________________________________________________ 5PINMAX6657MAX6658MAX6659NAME FUNCTION1

Page 14

MAX6657/MAX6658/MAX6659Detailed DescriptionThe MAX6657/MAX6658/MAX6659 are temperaturesensors designed to work in conjunction with a micro-processor o

Page 15

whether they are used or not. The DXN input is biasedat one VBEabove ground by an internal diode to set upthe ADC inputs for a differential measuremen

Page 16

MAX6657/MAX6658/MAX6659surements. The noise can be reduced with careful PCboard layout and proper external noise filtering. High-frequency EMI is best

Page 17

the conversion cycle is interrupted, and the tempera-ture registers are not updated. The previous data is notchanged and remains available.SMBus Digit