Rainbow-electronics MAX6692 User Manual

Browse online or download User Manual for Sensors Rainbow-electronics MAX6692. Rainbow Electronics MAX6692 User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 17
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
General Description
The MAX6648/MAX6692 are precise, two-channel digi-
tal temperature sensors. They accurately measure the
temperature of their own die and a remote PN junction,
and report the temperature in digital form using a 2-wire
serial interface. The remote PN junction is typically the
emitter-base junction of a common-collector PNP on a
CPU, FPGA, or ASIC.
The 2-wire serial interface accepts standard System
Management Bus (SMBus)™ write byte, read byte,
send byte, and receive byte commands to read the
temperature data and to program the alarm thresholds.
To enhance system reliability, the MAX6648/MAX6692
include an SMBus timeout. A fault queue prevents the
ALERT and OVERT outputs from setting until a fault has
been detected one, two, or three consecutive times
(programmable).
The MAX6648/MAX6692 provide two system alarms:
ALERT and OVERT. ALERT asserts when any of four tem-
perature conditions are violated: local overtemperature,
remote overtemperature, local undertemperature, or
remote undertemperature. OVERT asserts when the tem-
perature rises above the value in either of the two OVERT
limit registers. The OVERT output can be used to activate
a cooling fan, or to trigger a system shutdown.
Measurements can be done autonomously, with the
conversion rate programmed by the user, or in a single-
shot mode. The adjustable conversion rate allows the
user to optimize supply current and temperature
update rate to match system needs.
Remote accuracy is ±0.8°C maximum error between
+25°C and +125°C with no calibration needed. The
MAX6648/MAX6692 operate from -55°C to +125°C, and
measure temperatures between 0°C and +125°C. The
MAX6648 is available in an 8-pin µMAX package, and the
MAX6692 is available in 8-pin µMAX and SO packages.
Applications
Desktop Computers
Notebook Computers
Servers
Thin Clients
Workstations
Test and Measurement
Multichip Modules
Features
Dual Channel: Measures Remote and Local
Temperature
0.125°C Resolution
High Accuracy: ±0.8°C (max) from +25°C to
+125°C (Remote), and ±2°C (max) from +60°C to
+100°C (Local)
Two Alarm Outputs: ALERT and OVERT
Two Default OVERT Thresholds Available
MAX6648: +110°C
MAX6692: +85°C
Programmable Conversion Rate
SMBus-Compatible Interface
SMBus Timeout
Programmable Under/Overtemperature Alarm
Thresholds
MAX6648/MAX6692
Precision SMBus-Compatible Remote/Local
Temperature Sensors with Overtemperature Alarms
________________________________________________________________ Maxim Integrated Products 1
Ordering Information
V
CC
DXP
DXN
10k EACH
CLOCK
TO FAN DRIVER OR
SYSTEM SHUTDOWN
3.3V
DATA
INTERRUPTED TO µP
200
0.1µF
SDA
SCLK
ALERT
GND
2200pF
µP
MAX6648
MAX6692
OVERT
Typical Operating Circuit
19-2545; Rev 0; 8/02
For pricing, delivery, and ordering information, please contact Maxim/Dallas Direct! at
1-888-629-4642, or visit Maxim’s website at www.maxim-ic.com.
PART
TEMP RANGE
PIN-
PACKAGE
MEASURED
TEMP RANGE
MAX6648MUA*
-55°C to +125°C
8 µMAX
0°C to +125°C
MAX6692MUA
-55°C to +125°C
8 µMAX
0°C to +125°C
MAX6692MSA
-55°C to +125°C
8 SO
0°C to +125°C
SMBus is a trademark of Intel Corp.
Pin Configuration and Functional Diagram appear at end of
data sheet.
*Future product—contact factory for availability.
Page view 0
1 2 3 4 5 6 ... 16 17

Summary of Contents

Page 1 - MAX6648/MAX6692

General DescriptionThe MAX6648/MAX6692 are precise, two-channel digi-tal temperature sensors. They accurately measure thetemperature of their own die

Page 2

MAX6648/MAX6692Precision SMBus-Compatible Remote/LocalTemperature Sensors with Overtemperature Alarms10 ______________________________________________

Page 3

MAX6648/MAX6692Precision SMBus-Compatible Remote/LocalTemperature Sensors with Overtemperature Alarms_________________________________________________

Page 4

MAX6648/MAX6692Precision SMBus-Compatible Remote/LocalTemperature Sensors with Overtemperature Alarms12 ______________________________________________

Page 5

surements. The noise can be reduced with careful PCboard layout and proper external noise filtering.High-frequency EMI is best filtered at DXP and DXN

Page 6

MAX6648/MAX6692Precision SMBus-Compatible Remote/LocalTemperature Sensors with Overtemperature Alarms14 ______________________________________________

Page 7

MAX6648/MAX6692Precision SMBus-Compatible Remote/LocalTemperature Sensors with Overtemperature Alarms_________________________________________________

Page 8

MAX6648/MAX6692Precision SMBus-Compatible Remote/LocalTemperature Sensors with Overtemperature Alarms16 ______________________________________________

Page 9

MAX6648/MAX6692Precision SMBus-Compatible Remote/LocalTemperature Sensors with Overtemperature AlarmsMaxim cannot assume responsibility for use of any

Page 10

MAX6648/MAX6692Precision SMBus-Compatible Remote/LocalTemperature Sensors with Overtemperature Alarms2 _______________________________________________

Page 11

MAX6648/MAX6692Precision SMBus-Compatible Remote/LocalTemperature Sensors with Overtemperature Alarms_________________________________________________

Page 12

MAX6648/MAX6692Precision SMBus-Compatible Remote/LocalTemperature Sensors with Overtemperature Alarms4 _______________________________________________

Page 13

MAX6648/MAX6692Precision SMBus-Compatible Remote/LocalTemperature Sensors with Overtemperature Alarms_________________________________________________

Page 14

MAX6648/MAX6692nel. If the remote-diode channel is unused, connectDXP to DXN rather than leaving the pins open. The DXN input is biased to one VBEabov

Page 15

MAX6648/MAX6692Precision SMBus-Compatible Remote/LocalTemperature Sensors with Overtemperature Alarms_________________________________________________

Page 16 - Package Information

MAX6648/MAX6692Precision SMBus-Compatible Remote/LocalTemperature Sensors with Overtemperature Alarms8 _______________________________________________

Page 17 - 9LUCSP, 3x3.EPS

MAX6648/MAX6692Precision SMBus-Compatible Remote/LocalTemperature Sensors with Overtemperature Alarms_________________________________________________

Comments to this Manuals

No comments